Apaltek Shenzhen Co.,Ltd.was founded in 2010, With a high-quality provider of the thermal management solutions which has integrated in R&D, manufacturing, selling and servicing, and leading position in semicoductor of CPU GPU

IDC/server/workstation liquid cooling leading provider solution

Apaltek has adopted advanced cold plate technology for thermal management across data centers, servers, and workstations. Compared to traditional air cooling, cold plates provide superior heat transfer by directly interfacing with the heat source, enabling rapid thermal dissipation, lower operating temperatures, and improved system stability. Our solutions are designed with a compact footprint, low acoustic profile, and high scalability to support a wide range of deployment environments. Utilizing precision brazing and welding processes, Apaltek cold plates are engineered to minimize leakage risk while maintaining long term reliability. Both open loop and closed loop configurations are available, allowing seamless integration across diverse applications and performance requirements.

Open-loop liquid cooling series for server

Closed-loop liquid cooling series for Server

Server unit - Liquid cooling module
workstation - Liquid cooling module

Cold Plate Introduction

Performance

Β 

Pressure drop:

High


Power density:

High


cost:

High


Apply:

Data center CPU

Performance

Pressure drop:

Middle


Power density:

Low


cost:

Middle


Apply:

Wide large-scale cooling solar series

Performance

Pressure drop:

Low


Power density:

Middle


cost:

Low


Apply:

Low power, small class, current limiting class

Performance

Pressure drop:

Middle


Power density:

Middle


cost:

Low


Apply:

Inverter class

Cold Plate Introduction

Flexibly changing brackets and low costs to adjust to the different CPU brand

Intel Purley
Intel Whitley
Intel EGS
AMD SP3
AMD SP5

Radiator Design

APALTEK owns the international patent to pump inside the radiator

61dda09c-531c-4c7a-a803-6c0864f2ede9.jpg_366xaf

Tube Introduction

Performance

Evapotranspiration level:

High


Evapotranspiration description:

No evapotranspiration problem


Piping level

low


Pipe configuration description:

No flexibility, can not freely change the pipeline

Performance

Β 

Evapotranspiration level:

LOW


Evapotranspiration description:

Consideration needs to be given to evaporation and filling with sufficient coolant to meet lifetime maintenance requirements


Piping level

High


Pipe configuration description:

Easy to bend

Performance

Β 

Evapotranspiration level:

High


Evapotranspiration description:

Evapotranspiration is extremely low and no coolant injection is required for 5 years


Piping level:

Low


Pipe configuration description:

Easy to bend, but improper operation will press the pipe and cause blockage

Performance

Evapotranspiration level:

hIGH


Evapotranspiration description:

Evapotranspiration is extremely low and no coolant injection is required for 5 years


Piping level:

High


Pipe configuration description:

Easy to bend, tube ADAPTS to system layout

Quick connector introduction

Liquid cooling quick connectors usually connect in between components from liquid circulating systems, It is able to be quick connected and disconnected in between components without leaking,improve efficiency and reduce unnecessary workload which has caused by liquid drainage

Antifreeze Liquid Introduction

1:Same application wayΒ as vehicle
2:Refer to the working tempΒ to change proportion
Β It is combinedΒ with Ethylene Glycol and Water

Β 

Portions:

Antifreeze:25%(-25 ℃)
Preservative:0.5-1%Β 
Colorant:0.05-0.1%
Pure WaterΒ 

Application product

Open loop series
Closed loop series